top of page
Writer's pictureCentral Clare Plumbing Company

Is your home warm and comfy? Not if your pump looks like this!!!

Updated: Feb 17, 2021




If your radiators are not reaching optimum temperature your pump probably is in poor condition like the one in the photograph.


The picture depicts a blockage of about 40% causing poor circulation ultimately leading to less heat transfer around the system.

We changed this pump in Carraig Dubh, Ennis and achieved an average of 25-30 degree improvement to all the radiators on the system.



The thermal image in the photograph on the right was taken before we added a cleaner and drained the system.

We then replaced the existing Wilo pump for an energy saving Grunfoss UPS 3 15-50/65 self automating central heating pump. We also changed the pump valves as the system was drained down for the installation of thermostatic radiator valves to the bedrooms and inhibitor dosing.


As you can see in the before fitting the pump and gravity flushing the raise in temperature is 27 degrees on the living room radiator which is drop fed from the first floor. The radiator is at a good temperature but we could have achieved a better result if the system was power flushed.


The first photo is the replacement pumps we use. The 2nd photo is one I changed in Ennis. The 3rd photo

is a pump that was bodged up, so I replaced it for a customer in Corrofin ,Clare


Replacement Scrapyard A bodge I replaced

Good Bad Ugly


The dark shadow on the photo is magnetite which we can remove with our Magnaclense Rapid filter machine providing a Magnaclean unit is fitted to the system which we can fit for €180.oo prior to flush which start at €275.00 subject to survey. The customer is now considering a power flush in order to get the system back to a operate more efficient and economically, saving money on fuel and repair bills.



Photograph on the left was taken with a Flir Thermal

Camera the pump was changed. The beige area on the

radiator is a colder area full of magnetic debris. The

white area is clean. This system needs a Magnaclense

to get it back to peak condition and performance.


Photograph taken before pump change

Showing a 27 degree improvement

Dark shadow is magnetite which will

cause bad heat transfer


Grunfoss UPS 3 15-50/65

Fully automatic central

heating pump supplied &

fitted from €235.00. Extra

€25.00 for new valves.

Dose system with inhibitor

€25.00. We can offer a package

deal of a power flush, boiler service

and any other upgrades. Call us for

more details and book a survey to get

a full central heating health check.

46 views0 comments

Recent Posts

See All

Comentários


bottom of page